Komatsu — CHECKING CHARGE PRESSURE OF NITROGEN GAS IN ACCUMULATOR (FOR CONTROL CIRCUIT)

MAINTENANCE PROCEDURE MAINTENANCE METHOD OF RELEASING PRESSURE IN HYDRAULIC CIRCUIT NOTICE Carry out the following procedure to operate the work equipment control lever fully to the front, rear, left, and right within 15 seconds of stopping the engine. When the engine stops, the pressure in the accumulator gradually goes down, so the pressure can only be released immediately after the engine is stopped. 1. Place the work equipment on the ground. Close the crusher attachment jaws, etc. 2. Stop the engine. 3. Turn the starting switch to the ON position. 4.

Set the lock lever to the FREE position, then operate each work equipment control lever and attachment con- trol pedal (if equipped) fully to the front, rear, left, and right to release the pressure in the hydraulic circuit. 5. Set the lock lever to the LOCK position to lock the work equipment control levers and attachment control pedal (if equipped). 4-64