3.3. Operation Operation 12. Checking the central lubrication system: grease level and pressure relief hole in the safety valve Please ensure that the grease level in the grease reservoir is between the minimum (1) and maximum (2) markings. Top up with grease if the level is too low - see section "5.8.2. Maintenance upon demand" on page 5-22. Check pump and grease reservoir for leaks. Grease must not emerge from the pressure relief hole in the safety valve (3). If grease is leaking, there is a fault in the central lubrication system’s circuit. Please contact your local KOMATSU dealer if there are any leaks or faults. 2 3 1 13.
Check for loose bolts on ROPS Check for any loose or damaged bolts. If any loose bolts are found tighten them to 925 - 930 Nm. If any bolts are damaged, replace them with original Komatsu bolts. 14. Clean cab window Clean the cab window to ensure good visibility before operating the machine. 3-44