Komatsu — Check fuel level, add fuel

Operation 3.3. Operation Check before starting Perform daily the steps described in this section before starting the engine. Check coolant lever, top up coolant Normally, the radiator cap must not be opened. Always wait for the engine to cool down before checking the water level in the sub-tank. 1 1. The expansion tank (1) is located below the rise on the left- hand side of the machine. Check, whether the coolant level in the expansion tank (1) lies between the FULL and LOW markings. Where the coolant level is too low, top up by allow- ing water to flow into the expansion tank (1) through the filler neck until the coolant level reaches the FULL marking.

To do so unscrew the cover (3) in the grating and remove the cap (2). 2. After topping up put the cap back on again tightly and screw the cover back into place on the grating. 2 3 3. If the expansion tank (1) is empty, check for water leakage and check in addition collant level, then fill-up coolant. Check fuel level, add fuel G When adding fuel, never let the fuel overflow since this may cause a fire. If you spill fuel, clean it up thoroughly at once. 1. Turn the engine starting switch to the ON position, then check the fuel level at the fuel gauge (G). Then reset the starting switch to OFF. 2. Upon completion of work, add fuel until the fuel tank is full.

Details about opening and closing the cap, see section "3.2.5. Cap with lock" on page 3-33. For details of the recommended fuel, see section "5.4.2. Lubricants, fuels and filling capacities" on page 5-14. 3. After adding fuel, tighten the cap securely. Capacity of the fuel tank: 465 l. Refuelling from drum, see "Checking the fuel level, adding fuel" on page 5-41. 3-45 WARNING WARNING WARNING AE060954