5.8. Service procedure Maintenance 5.8.5. Every 100 hours service This coincides with the 50 hours service. Checking the oil level in the hydraulic tank, adding oil When the oil filler cap is removed, oil may spurt out, so stop the engine and wait for the oil temperature to cool down; then turn the cap slowly to release the internal pressure before removing the cap. If oil has been filled up above the H mark, stop the engine and wait for the hydraulic oil to cool down, then drain the excess oil from the drain plug. 1. Lower the bucket horizontally to the ground and stop the engine. Wait for 5 minutes, then check sight gauge (G). The oil level should be between the H and L marks.
NOTE Do not add oil if the level is above the H line. This will dam- age the hydraulic equipment and cause the oil to spurt out. 2. If the oil level is too low, open the cover above the increment and top up with oil at the oil-filling orifice (F). G For details of the oil to be used, see section "5.4. Lubricants and operating means" on page 5-13. F 5-46 WARNING WARNING