Maintenance 5.8. Service procedure Cleaning the inserts of the fresh air filter of the air- conditioning system When using compressed air, wear safety glasses and other protective clothes. After using the air-conditioning, the air filter should be cleaned. Switch off the air-conditioning before cleaning the insert. 1. Loosen bolt (1) and remove cover (2). 1 2 2. Loosen screw (3), then take out the insert (4) and clean it. 3. Blow compressed air (max. 7 bar) along the folds from the inside of the insert; repeat from the outside, then blow again from the inside. 4 NOTE 3 When re-assembling the insert; the arrow on top of the ele- ment must point toward the interior of the cab.
AE062430 5-47 CAUTION CAUTION