5.8. Service procedure Maintenance 5.8.6. Every 250 service hours Maintenance for every 50 and 100 hours should be performed at the same time. Checking and adjusting the fan belt and V-belt tension Check Tension is checked by placing a thumb on the back of the V-belt and pushing it inwards. This test should be conducted at a point in the middle between the fan’s belt pulley and the alternator. During the test the V-belt should be capable of being pushed in by approx. 17 - 19 mm. 17-19 mm Fan pulley Tension- pulley Crankshaft pulley GK100573 5-48