Komatsu — Check

5.8. Service procedure Maintenance 5.8.6. Every 250 service hours Maintenance for every 50 and 100 hours should be performed at the same time. Checking and adjusting the fan belt and V-belt tension Check Tension is checked by placing a thumb on the back of the V-belt and pushing it inwards. This test should be conducted at a point in the middle between the fan’s belt pulley and the alternator. During the test the V-belt should be capable of being pushed in by approx. 17 - 19 mm. 17-19 mm Fan pulley Tension- pulley Crankshaft pulley GK100573 5-48