GROUP 6 TROUBLESHOOTING GROUP 6 TROUBLESHOOTING 1. WHEN STARTING SWITCH IS TURNED ON, CLUSTER WHEN STARTING SWITCH IS TURNED ON, CLUSTER AND MONITOR AND MONITOR LAMP DOES NOT LAMP DOES NOT LIGHT UP LIGHT UP В Before carrying out below procedure, check all the related connectors are properly inserted and the fuse No.17 is not blown out and ON/OFF of bulb. В After checking, connect the disconnected connectors again immediately unless otherwise specified.
MONITOR 1 CN-57 CLUSTER 1 FUSE [CN-37] No.17 CN-56 Check voltage 760F7EL24 7-97 YES Check voltage between CN-56 (1), CN-57(1) and chassis NO Remedy Cause Remedy Defective cluster Defective monitor Disconnection in wiring harness or poor contact between CN-56 (1), CN-57 (1) and fuse No. 17 Replace Replace Repair or replace (after clean) YES 20 ~ 30 V NO 0 V