2. WHEN BATTERY LAMP LIGHTS UP WHEN BATTERY LAMP LIGHTS UP (engine is started) В Before carrying out below procedure, check all the related connectors are properly inserted. В After checking, connect the disconnected connectors again immediately unless otherwise specified. CONTROLLER(MCU) ALTERNATOR " 2 " TERMINAL CN-58B Check valtage 760F7EL38 7-98 YES Check voltage YES between CN-58B (B33) and chassis NO Voltage : 27.5~30V Check voltage YES between CN-4 (18) and chassis Voltage : 26~30V Check voltage between NO alternator terminal "2" and chassis Voltage : 26~30V Starting switch :
ON NO Remedy Cause Remedy Defective controller Disconnection in wiring harness or poor contact between CN-58B (B33) and CN-4 (18) Disconnection in wiring harness or poor contact between CN-4 (18) and alternator terminal " 2 " Defective alternator Replace Repair or replace (after clean) Repair or replace (after clean) Replace B33 18 CN-4 YES 20 ~ 30 V NO 0 V