Komatsu — EVERY 250 HOURS SERVICE

. MAINTENANCE SERVICE PROCEDURE WHEN IT IS IMPOSSIBLE TO CHECK ELECTROLYTE LEVEL FROM SIDE OF BATTERY or there is no display of the UPPER 4 - 45 If it i s impossible to check the electrolyte lev LEVEL line on the s ide of the battery, check a 1. Open the cover of the battery box. There are two b attery boxes: One on eac h side at the rear o f the mach 2. Remove cap (1) at the top of the battery, lo ok through the wate iller port, and c heck the electrolyte surfac e. If the electrolyt does not reach the sleeve, add distilled w ater so that the lev eaches the bott om of the sleeve (UPPER LEVEL line) witho ail. f distilled water 3.

I distilled water a Use the diagram be low for reference, and che ck if the electrolyt e reaches t he bottom of the 4. After adding dis tilled water, tighten cap (1 REMARK If water is added to above the bottom tip of the sleeve, use a pipette to remo ve electrolyte. N eutralize the rem oved electrolyte with sod ium bicarbonate, then flus h it away with a large amount of water. If necessary, contact your Komatsu distributor or your battery maker. WHEN IT IS POSSIBLE TO USE INDICATOR TO CHECK ELECTROLYTE LEV EL If it i s possible to us e an indicator to check the electrolyte level, follow the i nstructions given