30.1 DESCRIPTION AND OPERATION OF COOLANT THERMOSTAT Thermostat Operating Modes The coolant from the radiator and the radiator bypass mix in the thermostat housing. The thermostat regulates the temperature of this mixed flow circuit. Three different operating conditions occur due to the coolant mixed flow temperature: Bypass mode: When the coolant mixed flow temperature is below 87°C (188°F), the circulating thermostat is closed. The coolant circulates through the radiator bypass to the coolant thermostat. None of the flow passes through the radiator. Mixed mode:

For a coolant mixed flow temperature above 87°C (188°F) to and less than 95°C (203°F), the circulating thermostat opens partially and the coolant flows at the same time through the engine radiator and the radiator bypass to the coolant thermostat . Radiator operation: When the coolant inlet temperature is above 95°C (203°F) the circulating thermostat is completely open. The coolant flows through the radiator to the coolant thermostat. None of the flow passes through the radiator bypass. Other minor coolant loops exist in addition to those described above. The flow through these loops are unaffected by the position of the coolant thermostat.

These loops include the flow through the vehicle cab heater, vehicle bunk heater, the EGR actuator, and the doser. All information subject to change without notice. 30-4 DDC-SVC-MAN-0081 2010 Copyright © 2010 DETROIT DIESEL CORPORATION