Cummins — Cummins CM2220 R2.8 Installation Guide R101B

Electrical System R2.8 CM2220 R101B Page 1-36 Section 1 - Installation by Subsystem Figure 2 - Accelerator Pedal Spacing It is recommended the spacing between the brake pedal and electronic accelerator pedal be no less than the spacing of the mechanical pedal that was removed. Additional mounting information can be found by following the link below. The accelerator pedal that is included in the kit is WM 540 - Suspended Electronic Accelerator Pedal. NOTE: http://www.tectran.com/images/pdf/CAT_williams_catalog_download.pdf Electrical System (387-011) Battery The R2.8 CM2220 R101B engine is a 12 volt, negative ground system only .

Recommended Battery Capacity Starter The engine kit includes an engine mounted 12 volt starting motor. Make sure the batteries are disconnected prior to installing the starting motor cables. To buy Cummins Parts and Service Manuals, Training Guides, or Tools go to our website at https://store.cummins.com Ambient Temperature -18°C [0°F] -29°C [-20°F] System Voltage Cold Cranking Amperes (CCA) Reserve Capacity (minutes)1 Cold Cranking Amperes Reserve Capacity (minutes)1 12 VDC 800 180 950 180 The number of plates within a given battery size determines reserve capacity. Reserve capacity is the length of time for which a battery at 27°C [81°F] can supply 25 amperes at 10.5 VDC or greater.

Specific Gravity at 27°C [81°F] State of Charge 1.260 to 1.280 100% 1.230 to 1.250 75% 1.200 to 1.220 50% 1.170 to 1.190 25% 1.110 to 1.130 Discharged