Electrical System R2.8 CM2220 R101B Page 1-42 Section 1 - Installation by Subsystem The power for the ECM, black 5 amp wire from the keyswitch, must provide a minimum of 12 volts in the run position and during engine cranking. The lamp circuits require power from the keyswitch to each lamp, with the ECM providing a path to ground via a sink circuit as engine conditions dictate. Any unused wire leads should be taped off to prevent water intrusion into the unused circuit and properly secured. Figure 7 below shows available locations for supporting electrical harness only . The location and size will not allow for any brackets over one pound to be attached.
Figure 7 - Supporting Locations 1 Valve cover studded capscrews, M6 x 1.0, 20 mm threaded 2 Lifting bracket studded capcscrews, M8 x 1.25, 20 mm threaded 3 6.5 mm [0.26 in] through hole 4 Air intake connection studded capscrews, M6 x 1.0, 20 mm threaded.
To buy Cummins Parts and Service Manuals, Training Guides, or Tools go to our website at https://store.cummins.com Circuit Wiring Table Name Description Wire Color Pin Number on ECM Connector Keyswitch 12 volt power to ECM from keyswitch in CRANK or RUN position Black 41 Lamp, STOP ENGINE Critical Engine Issue, Stop Engine Also Available on provided Murphy Gage Green 49 Lamp, WARNING Engine Issue Detected, Service Soon Also Available on provided Murphy Gage Blue 36 Lamp, WAIT-TO- START Do not start the engine until the lamp is not illuminated Also Available on provided Murphy Gage Yellow 35 Lamp, MIL An emission related engine issue has been detected Not used on the R2.8 CM2220 R101B product White 22 Tachometer Output to drive tachometer White 9 Fan-Hi Signal Fan supply +12 volt Brown 33 Fan Ground Fan ground White 34