R2.8 CM2220 R101B Electrical System Section 1 - Installation by Subsystem Page 1-45 2 Permissible mounting orientation angle range (135 degrees) 3 Gravity Electric Starting Aid 4 Prohibited mounting orientation angle range (225 degrees). To reduce the possibility of personal injury and property damage, never use starting fluid if the grid heater option is used. Starting fluid, which contains ether, can cause an explosion. WARNING The grid heater is also referred to as an electric starting aid as illustrated on the warning label placed on the top of the engine. See Figure 11.
Figure 11 - Grid Heater Warning Label To enhance the engine starting at cold temperature, an electric grid heater is standard on the engine. The grid heater system must be installed and functional on the vehicle. A grid heater high current relay is provided as part of the R 2.8 CM2220 R101B engine kit. The grid heater relay is controlled by the ECM. The high current power cable with the fusible link must be used for the connection to battery positive post, Figure 2. The other cable is for connection between the grid heater relay and the grid heater post on the engine. The grid heater relay must not be mounted on the engine.
The recommended mounting orientation of the grid heater relay is with the posts pointed upward or horizontal. For proper operation of the grid heater, the control circuit to the ECM must be connected to the wiring harness. The o- ring connectors are marked "Grid Heater" on the wiring harness. To buy Cummins Parts and Service Manuals, Training Guides, or Tools go to our website at https://store.cummins.com