COMPONENTS (S/N 522311001 & ABOVE) Figure 70-50-3 Identification Figure 70-50-1 2 1 P-36870 P-40348 1 Receiver/Drier: The receiver/drier (Item 1) [Figure 70-50- 3] is the unit that receives the liquid refrigerant from the condenser and removes moisture and foreign matter from the system. It also serves as a storage tank for the extra liquid refrigerant until it is needed by the evaporator. Compressor: The compressor (Item 1) [Figure 70-50-1] is the pump that circulates the refrigerant throughout the system. It raises the pressure of the refrigerant for heat transfer through the condenser and evaporator. Pressure Switch:
The pressure switch (Item 2) [Figure 70-50-3] will disengage the compressor clutch at high pressure readings on the high side, or at low pressure on the high side, which indicates loss of refrigerant. NOTE: The A/C system (compressor) is recommended to be turned on for at least five minutes weekly throughout the year to lubricate the internal components. Figure 70-50-4 Figure 70-50-2 1 1 P-40349 P-36869 Heater/Evaporator Unit: The heater/evaporator unit (Item 1) [Figure 70-50-4] is located under the operator seat in the excavator cab. The unit delivers the cold air for the A/ C and warm air for heat into the cab. The unit contains the blower, heat & A/C coils, thermostat and expansion valve.
Condenser: The condenser (Item 1) [Figure 70-50-2] is the unit that receives the high pressure, high temperature refrigerant vapor from the compressor and condenses it into a high temperature liquid. 442 Excavator 70-50-1 Service Manual