Bobcat Company 442 — Blower Motor Does Not Operate

SYSTEM TROUBLESHOOTING CHART Blower Motor Does Not Operate Blower motor operators normally, but air flow is insufficient Insufficient cooling although air flow and compressor operation are normal The compressor does not operate at all, or operates improperly 442 Excavator 70-100-1 Service Manual POSSIBLE CAUSE INSPECTION SOLUTION 1. Blown Fuse. Inspect Replace fuse/repair wiring. 2. Broken wiring or bad connection. Check the fan motor ground and connectors. Repair the wiring or connector. 3. Fan motor malfunction. Check the lead wires from the motor with a circuit tester. Replace Motor. 4. Resistor malfunction. Check resistor using a circuit tester. Replace Resistor. 5.

Fan motor switch malfunction. Check power into and out of the fan switch. Replace Fan Switch. POSSIBLE CAUSE INSPECTION SOLUTION 1. Evaporator inlet obstruction Check evaporator for plugging. Remove obstruction and clean evaporator fins with air or water. 2. Air leak. Check to make sure air hoses are properly hooked to louvers and air ducts. Repair or adjust. 3. Defective thermo. switch (frozen evaporator). Check thermostat using a circuit tester. Replace thermostat. POSSIBLE CAUSE INSPECTION SOLUTION 1. System low on refrigerant. The high side pressure will be low and bubbles may be present in sight glass on receiver drier. Repair any leaks and recharge the refrigerant to the correct level.

2. Excessive refrigerant. The high pressure side pressure will be high. Use refrigerant recovery equip- ment to capture excess refriger- ant charge to the correct refrigerant level. POSSIBLE CAUSE INSPECTION SOLUTION 1. Loose drive belt. The belt is vibrating or oscillating. Adjust tension. 2. Internal compressor malfunction. The compressor is locked up and the belt slips. Replace compressor. Magnetic clutch related 3. Low battery voltage. Clutch slips. Recharge the battery. 4. Faulty coil. Clutch slips. Replace the magnetic clutch. 5. Oil on the clutch surface. Clutch slips. Replace or clean the clutch sur- face. 6. Open oil.

Clutch does not engage and there is not reading when a circuit tester is connected between the coil and terminals. Replace clutch. 7. Broken wiring or poor ground. Clutch will not engage. Inspect the ground and connections. Repair. 8. Wiring harness components. Test the conductance of the pressure switch, thermostat, relay, etc. Check operation.