RELIEF VALVES Figure 20-30-3 Description Figure 20-30-1 1 1 P-32843 The backup relief valve (Item 1) [Figure 20-30-3] is set at 4350 PSI (300 bar), 290 PSI (20 bar) higher than the load sense relief. P-33373 The gear pump circuit has one main relief valve (Item 1) [Figure 20-30-1] located on the three spool valve. The backup relief valve and load sense relief valve are tested and adjusted during the piston pump testing and adjusting. (See Pump Testing on Page 20-50-6 or See Pump Testing on Page 20-52-5.) The relief valve is factory set at 3335 PSI (230 bar).
Figure 20-30-2 1 P-33367 The piston pump circuit has one load sense relief valve (Item 1) [Figure 20-30-2] and one backup relief valve (Item 1) [Figure 20-30-3] located on the six spool valve. The load sense relief valve (Item 1) [Figure 20-30-2] is factory set at 4060 PSI (280 bar). 442 Excavator 20-30-1 Service Manual