Bobcat Company 442 — Adjustment Procedure

PORT RELIEF VALVES Figure 20-31-2 Adjustment Procedure IMPORTANT When repairing hydrostatic and hydraulic systems, clean the work area before disassembly and keep all parts clean. Always use caps and plugs on hoses, tubelines and ports to keep dirt out. Dirt can quickly damage the system. I-2003-0888 1 P-35504 A portable hydraulic hand pump will be used to test the work port relief valves. The hand pump must have clean hydraulic fluid that is compatible with the Bobcat hydraulic fluid. Remove the protective end cap (Item 1) [Figure 20-31- 2] . NOTE: The valve is shown removed from the excavator for photo clarity.

Figure 20-31-3 Figure 20-31-1 1 2 P-35503 Loosen the lock nut (Item 1) [Figure 20-31-3] . P-35502 Install the hand pump, hose and a pressure gauge (minimum of 5000 PSI (345 bar) into the valve section work port in which the port relief valve is located [Figure 20-31-1] . Pressurize this section with the hand pump until the port relief valve opens and record the pressure reading. Turn the adjusting screw (Item 2) [Figure 20-31-3] clockwise to increase the pressure and counterclockwise to reduce the pressure. NOTE: One-quarter turn is approximately 1000 PSI (69 bar). When the correct pressure setting is obtained, tighten the locknut while holding the adjustment screw from turning.

If the port relief pressure setting needs to be adjusted, release the hand pump pressure valve. Adjust the port relief valve until the correct setting is obtained. Install the end cap. 442 Excavator 20-31-1 Service Manual