Figure 20-50-68 Install the dust cap (Item 1) [Figure 20-50-65] . NOTE: After the pump assembly is installed in the machine, the torque motor must be tested and adjusted. See “Initial Torque Limiter Valve Setting” on page 29. for torque limiter adjustment) Figure 20-50-66 2 1 2 1 P-35321 Put oil on the metering spool (Item 1) and install in the control spool (Item 2) [Figure 20-50-68] . NOTE: The end of the metering spool with the three rings enters the control spool first. N-23333 Install the two springs (Items 1 & 2) [Figure 20-50-66] in the valve body. NOTE: Install the big spring first and the small spring second.
442 Excavator 20-50-26 Service Manual HYDRAULIC PISTON PUMP (S/N 522311001 & Figure 20-50-67 ABOVE) (CONT’D) Torque Limiter Valve Assembly (Cont’d) Figure 20-50-65 1 N-23332 Install the spring seat (Item 1) [Figure 20-50-67] in the 1 valve body with the ball side facing toward the control P-35324 spool. 1 P-35324 valve body with the ball side facing toward the control spool. P-35324