HYDRAULIC PISTON PUMP (S/N 528911001 & ABOVE AND S/N 528611001 & ABOVE) (CONT’D) Figure 20-52-1 Testing Information The testing of the piston pump must be done in the following order: 5 Torque limiter supply pressure Pump margin pressure Load sense relief valve Torque Limiter 1 3 All testing is done with the hydraulic oil at 122 ° to 140° F (50° to 60° C). 2 4 P-58652 Check and adjust as needed the engine high idle before any hydraulic testing. Item 1 [Figure 20-52-1] : Female 24 ° DIN to male 37 ° JIC flare P/N 6698092. The hydraulic hoses, tubelines and fittings on the 442 Excavator are 24 ° DIN cone metric fittings.
To test the torque limiter order the following parts to adapt the metric fittings to 37 ° JIC flare fittings: Item 2 [Figure 20-52-1] : Male 24 ° DIN to male 37 ° JIC flare P/N 6698093. Order the following parts from your Bobcat dealer: Item 3 [Figure 20-52-1] : Male British pipe thread to male 37 ° JIC flare P/N 6698094. Item 4 [Figure 20-52-1] : British bonded seal P/N 6698095. Item 5 [Figure 20-52-1] : Female 37 ° JIC flare cap P/N 36K-8. MEL1610 Hose Kit (not shown). 442 Excavator 20-52-4 Service Manual