HYDRAULIC PISTON PUMP (S/N 528911001 & ABOVE AND S/N 528611001 & ABOVE) (CONT’D) Install the protective cap on the hydraulic pump torque limiter. Pump Testing (Cont’d) Remove the hydraulic tester and fittings. Figure 20-52-26 Install the reservoir breather. Install the supply hose on the hydraulic control valve. Figure 20-52-27 1 2 1 P-58651 Check the 13 mm nut (Item 1) [Figure 20-52-26] to be sure it is locked in place. P-58097 Adjust the flow at the hydraulic pump torque limiter by loosening the 27 mm nut (Item 2) [Figure 20-52-26] With an Allen wrench adjust the flow at low pressure .
Adjust the pump margin spool (Item 1) [Figure 20-52-27] back to the original position (approximately 6 turns out). When the proper flow is obtained, 41 GPM (155 L/min) at 1450 PSI (100 bar), lock the 27 mm nut (Item 2) [Figure 20-52-26] . Retest and adjust the pump margin spool as needed. (See Pump Margin Pressure Adjustment on Page 20-52- 6.) NOTE: Changing the flow at low pressure (27 mm nut) will affect flow at high pressure (13 mm nut). ALL PUMP ADJUSTMENTS ARE NOW COMPLETED. Turn the hydraulic tester flow control (Item 2) clockwise until the gauge (Item 3) [Figure 20-52-24 on Page 11] reads 3480 PSI (240 bar). NOTE:
Do not exceed 4350 PSI (300 bar) with the hydraulic tester or the pump will be damaged. The gauge should show 19 GPM (72 L/min) which is flow at high pressure. Adjust the flow at the hydraulic pump torque limiter. Loosen the 13 mm nut (Item 1) [Figure 20-52-26] and with an Allen wrench adjust the flow at high pressure . When the proper flow is obtained, 19 GPM (72 L/min) at 3480 PSI (240 bar), lock the 13 mm nut (Item 1) [Figure 20-52-26] . NOTE: If adjustments were made to flow at high pressure verify the flow at low pressure . 442 Excavator 20-52-12 Service Manual