Bobcat Company 442 — Removal And Installation

BATTERY (CONT’D) Removal And Installation Servicing (Cont’d) Figure 50-20-5 Figure 50-20-4 1 P-32701 Pull up on and remove the floormat (Item 1) [Figure 50- 20-5] . Clean the battery terminals and cable ends even when installing a new battery [Figure 50-20-4] . Figure 50-20-6 Check for broken or loose connections. If the battery cables are removed for any reason, disconnect the negative (-) cable first. When installing the battery cables, make the last connection the negative (-) cable to the battery. 1 If electrolyte level is lower than 1/2 inch (13 mm) above the plates, add distilled water only. Put Battery Saver or grease on the battery terminals and cable ends to prevent corrosion.

P-32702 WARNING Remove the battery compartment cover (Item 1) [Figure 50-20-6] . Batteries contain acid which burns eyes and skin on contact. Wear goggles, protective clothing and rubber gloves to keep acid off body. In case of acid contact, wash immediately with water. In case of eye contact get prompt medical attention and wash eye with clean, cool water for at least 15 minutes. If electrolyte is taken internally drink large quantities of water or milk! DO NOT induce vomiting. Get prompt medical attention. W-2065-1296 442 Excavator 50-20-2 Service Manual P9590 P9590