BATTERY (CONT’D) Figure 50-20-8 Removal And Installation (Cont’d) 1 1 2 Figure 50-20-7 2 1 P-32704 Remove the nuts (Item 1) and remove the hold down clamp (Item 2) [Figure 50-20-8] . P-32703 Disconnect the negative (-) cable (Item 1) [Figure 50-20- 7] first. Remove the battery. Always clean the terminals and the cable ends. Disconnect the positive (+) cable (Item 2) [Figure 50-20- 7] . Install the battery. Install the hold down clamp and tighten the bolts. Connect the battery cables. Connect the negative (-) cable (Item 1) [Figure 50-20-7] last to prevent sparks. WARNING Batteries contain acid which burns eyes and skin on contact.
Wear goggles, protective clothing and rubber gloves to keep acid off body. In case of acid contact, wash immediately with water. In case of eye contact get prompt medical attention and wash eye with clean, cool water for at least 15 minutes. If electrolyte is taken internally drink large quantities of water or milk! DO NOT induce vomiting. Get prompt medical attention. W-2065-1296 442 Excavator 50-20-3 Service Manual