Bobcat Company 442 — Rotor Continuity Test

ALTERNATOR (CONT'D) Stator Ground Test Disassembly (Cont’d) Figure 50-30-51 Figure 50-30-49 1 P-63529 P-63401 Touch one probe to a bare stator lead and the other probe to the bare metal surface of the stator [Figure 50- 30-51] . Remove the bushing (Item 1) [Figure 50-30-49] . Stator Continuity Test There should be no continuity. Use an ohmmeter to test the stator. Replace the stator if there is continuity. Figure 50-30-50 Rotor Continuity Test Figure 50-30-52 P-63528 Touch the probes to two of the bare stator wires [Figure 50-30-50] . P-63307 Move one of the probes to the third wire. Touch the probes to the slip rings [Figure 50-30-52] . The readings should be the same.

The ohmmeter should read between 3.0 - 4.0 ohms. If there is no continuity replace the rotor. If there is no continuity, replace the stator. 442 Excavator 50-30-16 Service Manual