Bobcat Company 442 — Capacitor Continuity Test

ALTERNATOR (CONT’D) Rotor Ground Test Figure 50-30-53 P-63308 Touch one probe to one of the slip rings and the other probe to the rotor shaft [Figure 50-30-53] . There should be no continuity. Replace the rotor if there is continuity. Capacitor Continuity Test Figure 50-30-54 P-63610 1 2 Check the capacitor for continuity between the mounting tab (Item 1) and the lead (Item 2) [Figure 50-30-54] . If there is continuity the capacitor is bad. Check the capacitor by connecting an ohmmeter between the mounting tab and the lead. The ohmmeter will initially show movement and then return to indicating no continuity as the capacitor is charged.

Discharge the capacitor by grounding the lead to the tab before installation. 442 Excavator 50-30-17 Service Manual