Bobcat Company 442 — Inspection And Repair (All Models)

STARTER (CONT’D) Figure 50-40-39 Inspection And Repair (All Models) Inspect the brush cover for discoloration, indicating the starter has been overheated. Inspect the pinion teeth for wear and damage. Figure 50-40-37 P-63368 Armature Winding Continuity Test: Use a circuit tester, touch the probes to two commutator segments [Figure 50-40-39] . There must be continuity at any point. If there is no continuity, the winding is open-circuited, replace the armature. Figure 50-40-40 Armature Short-Circuit Test: Use a growler tester, put the armature on the growler and hold a hack saw blade against the armature core while slowly rotating the armature [Figure 50-40-37] .

A short-circuited armature causes the blade to vibrate and be attracted to the core. An armature which is short-circuited must be replaced. Figure 50-40-38 B-14458 Commutator Run-Out Test: Check the commutator run- out as shown in [Figure 50-40-40] . Service Limit - 0.020 inch (0,4 mm) If the commutator exceeds the service limit, repair as needed. P-63367 Armature Winding Ground Test: Use a circuit tester, touch one probe to a commutator segment and the other probe to the armature core [Figure 50-40-38] . There should be no continuity. If there is continuity, the armature is grounded and must be replaced. 442 Excavator 50-40-12 Service Manual B-14455 B-14455