STARTER (CONT’D) Figure 50-40-42 Inspection And Repair (All Models) (Cont’d) Figure 50-40-41 1 P-63369 Field Winding Ground Test: Use a circuit tester, touch one probe to the field winding end of the brush and the other probe to the surface of the frame [Figure 50-40- 42] . There should be no continuity. If there is continuity, the field windings are grounded. B-14460 Measure the segment mica depth (Item 1) [Figure 50-40- 41] . Service Limit - 0.008 inch (0,2 mm) Replace the field windings. If it is worn, replace the armature. Figure 50-40-43 Check the commutator surface for burned spots which usually indicates an open-circuit, and correct it using #400 sand paper.
Check the field windings for wear and damage. Check all the connections for clean and tight solder joints. P-63375 Field Windings Continuity Test: Use a circuit tester, touch one probe to the wire and the other probe to the brush [Figure 50-40-43] . There must be continuity. If there is no continuity, the field windings are open-circuited. Replace the yoke if the field windings have an open circuit. Inspect the brushes for wear and damage. Replace the brush holder or yoke assembly if the brushes are worn or damaged. Check brush springs, for damage or rust. Replace as needed. 442 Excavator 50-40-13 Service Manual