ENGINE COMPONENTS AND TESTING (S/N 528911001 & ABOVE AND S/N 528611001 & ABOVE) (CONT’D) Fuel Shutoff Solenoid Checking Figure 60-51-13 1 P-58310 Disconnect the wire harness (Item 1) [Figure 60-51-13] from the fuel shutoff solenoid. Use a multi meter to measure the resistance of the fuel shutoff solenoid. Figure 60-51-14 P-58316 Connect the meter leads (Item 1) [Figure 60-51-14] to the terminals. The reading must be approximately 3.5 ohms. If the resistance is zero ohms the solenoid has a short circuit. If the resistance is infinite, the coil in the solenoid is broken. 442 Excavator 60-51-5 Service Manual