Bobcat Company 442 — Fuel Shutoff Solenoid Removal And Installation

ENGINE COMPONENTS AND TESTING (S/N 528911001 & ABOVE AND S/N 528611001 & ABOVE) (CONT’D) Figure 60-51-17 Fuel Shutoff Solenoid Removal And Installation 1 Figure 60-51-15 1 2 3 P-58318 Remove the O-ring (Item 1) [Figure 60-51-17] . Check the solenoid spring (Item 2) and linkage (Item 3) [Figure 60-51-17] . P-58310 Disconnect the wire harness (Item 1) [Figure 60-51-15] . NOTE: When installing the fuel shutoff solenoid in the engine, the linkage (Item 3) [Figure 60-51-17] must engage the fuel control rack. Figure 60-51-16 2 3 1 P-58317 Cut and remove the cable tie (Item 1). Remove the two bolts (Item 2) and remove the solenoid (Item 3) [Figure 60-51-16] . Installation:

Tighten the bolts to 10-12 ft.-lb. (13.5-16.3 N•m) torque. 442 Excavator 60-51-6 Service Manual