MAINTENANCE 1. Stop the machine on level ground, then stop the engine. 2. Open engine hood (1). 3. Check that the cooling water temperature has gone down enough to make it possible to touch the radiator cap surface by hand, then turn radiator cap (2) slowly until it contacts the stopper to release the pressure. 4. Following this, push radiator cap (2), turn it until it contacts the stopper, then remove it. 5. Remove the undercover, then set the container under drain valve (3) to catch the coolant mixture. Open drain valve (3) at the bottom of the radiator and drain the coolant. 6. After draining the coolant, close drain valve (3), and fill with city water.
When the radiator is full, start the engine and run at low idling to raise the temperature to at least 90°C (194°F), then continue to run for approximately ten minutes. 7. Stop the engine and open drain valve (3) to drain the coolant. 8. After draining the water, clean the radiator with detergent. For the cleaning method, follow the instruction of detergent.. 9. Close drain valve (3). 10. Install the undercover. 11. Add Supercoolant through the water filler up to the bottom of the filler port. For details of the Supercoolant density, see the “Coolant Density Table” on page 3-30. 12.
Run the engine at low idling for five minutes to remove the air from the water, then run at high idling for five minutes. (Leave radiator cap (2) removed when doing this.) PC200LC-8 3-31