MAINTENANCE Adjust Bucket Clearance • It is dangerous if the work equipment is mistakenly moved when adjusting the bucket clearance. • Set the work equipment in a stable condition, stop the engine, then set lock lever (1) securely to the LOCK position (L). 1. Set the work equipment to the position shown in the diagram on the right, then stop the engine and set the lock lever (1) to the LOCK position (L). 2. Shift O-ring (1) and measure the amount of play “a”. Measurement is easier if you move the bucket to one side so that all the play can be measured at one place (the left side in the diagram). Use a clearance gauge for easy and accurate measurement. 3.
Loosen four plate mounting bolts (2), and loosen plate (3). The shim is a split type, so the operation can be carried out without removing the bolts. 4. Remove shim (4) corresponding to the amount of play “a” measured above. [Example] In the case of play of 3 mm (0.118 in), remove two 1.0 mm (0.039 in) shims and one 0.5 mm (0.020 in) shim. Play becomes 0.5 mm (0.020 in). For shim (4), two types of 1.0 mm (0.039 in) and 0.5 mm (0.020 in) are used. When play “a” is smaller than one shim, do not carry out any maintenance. 5. Tighten the four bolts (2). If the bolts (2) are too stiff to tighten, pull out pin stopper bolt (5) for easier tightening.
Remark Item (6) is the arm Item (7) is the bucket PC200LC-8 3-41