MAINTENANCE Bleeding Air from Hydraulic System For details, See “STARTING ENGINE” on page 2-134. If it is necessary to refer to the items for starting the engine, moving the machine off, steering, or stopping, see the OPERATION section. 1. Bleeding air from pump A. Loosen air bleed plug (1) and check that oil oozes out from the air bleeder. B. If the oil does not ooze out, remove the drain hose from the hydraulic pump case and fill the pump case completely with hydraulic oil through drain port (2). Hold the removed hose firmly, keeping the mouthpiece higher than the oil level in the hydraulic tank so that oil will not spill out of the hose. C.

After completing the air bleed operation, tighten air bleed plug (1) and install the drain hose. Remark If the drain hose is installed first, oil will spurt out from plug hole (1). If the pump is operated without filling the pump case with hydraulic oil, abnormal heat will be generated and this may cause unexpected damage to the pump. 2. Starting engine Start the engine, referring to “STARTING ENGINE” on page 2-134. Run the engine at low idle for ten minutes after starting, then start operations. 3. Bleeding air from cylinders A. Run the engine at low idle, and extend and retract each cylinder four to five times, taking care that a cylinder is not moved to the end of its stroke.

(Stop the cylinder approximately 100 mm (3.9 in) short of its stroke end) B. Next, operate each cylinder three to four times to the end of its stroke. C. Finally, operate each cylinder four to five times to the end of its stroke to completely remove the air. Remark If the engine is run at high speed immediately after startup or a cylinder is pushed up to its stroke end, air taken inside the cylinder may cause damage to the piston packing. 4. Bleeding air from swing motor A. Run the engine at low idling, loosen hose (1) at port S, and check that oil oozes out from port S hose (1). Remark Do not operate the swing under any circumstances. B.

If oil does not ooze out, stop the engine, remove port S hose (1), and fill the inside of the motor case with hydraulic oil. C. After completely bleeding the air, tighten port S hose (1). D. Run the engine at low idle and slowly swing at least two times uniformly to the left and right. This will automatically bleed the air. PC200LC-8 3-49