MAINTENANCE Every 2000 Hours Maintenance Maintenance for every 100, 250, 500 and 1000 hours service should be carried out at the same time. Change Oil in Final Drive Case • Immediately after the engine is stopped, the oil and parts are at high temperature. For this reason, if you touch the oil or parts immediately after the engine is stopped, you will suffer burns. Wait for the temperature to go down before starting the operation. • If there is pressure remaining inside the case, the oil or plug may fly out. Loosen the plug slowly to release the pressure. To avoid danger, do not stand directly in front of the plug. Refill capacity PC200 (each): 3.3 liters (0.87 US gal) Prepare a handle. 1.
Set the TOP mark at the top, with the TOP mark and plug (P) perpendicular to the ground surface. 2. Set a container under plug (P) to catch the oil. 3. Remove plugs (P) and (F) with the handle and drain the oil. Remark Check the O-rings in the plugs for damage. If necessary, replace with new ones. 4. Tighten plug (P). 5. Add oil through the hole of plug (F). 6. When oil begins to overflow from the plug (F) hole, install plug (F). Plugs (P) and (F ) torque: . . . . . .68.6 ± 9.8 N·m (50.6 ± 7.2 lb/ft) Remark There are two plugs (F). Add oil through the one easier to fill oil and through which no internal gears are to be seen. 3-78 PC200LC-8