Komatsu — Checking Charge Pressure of Nitrogen Gas in Accumulator (For Control Circuit)

MAINTENANCE Checking Charge Pressure of Nitrogen Gas in Accumulator (For Control Circuit) The accumulator is charged with high-pressure nitrogen gas, so mistaken operation may cause an explosion, which will lead to serious injury or damage. When handling the accumulator, always do as follows. • The pressure in the hydraulic circuit cannot be completely removed. When removing the hydraulic equipment, do not stand in the direction that the oil spurts out when carrying out the operation. In addition, loosen the bolts slowly when carrying out the operation. • Do not disassemble the accumulator. • Do not bring it near flame or dispose of it in fire. • Do not make holes in it or weld it.

• Do not hit it, roll it, or subject it to any impact. When disposing of the accumulator, the gas must be released. Please contact your Komatsu distributor to have this work carried out. Remark If the nitrogen gas charge pressure in the accumulator is low and operations are continued, it will become impossible to release the remaining pressure inside the hydraulic circuit if a failure occurs on the machine. Function Of Accumulator The accumulator stores the pressure in the control circuit. Even after the engine is stopped, the control circuit can be operated, so the following actions are possible.

If the control lever is operated in the direction to lower the work equipment, it is possible for the work equipment to go down under its own weight. The pressure in the hydraulic circuit can be released. The accumulator is installed to the position shown in the diagram on the right. 3-80 PC200LC-8