Komatsu — EVERY 250 HOURS SERVICE

c. FAN BELT 1. The belt tension should normally deflect by about 10 mm (a) when pressed with the finger at a point midway between the alternator (b) and the fan pulley (c) (approx. 6 kg). (d): Crankshaft pulley 2. To adjust the belt tension, loosen bolt (1) and nut (2) and shift alternator (3) slightly. 3. After adjustment, tighten bolt (1) and nut (2) securely. * When adjusting the V-belt, do not attempt to push alternator (3) directly with a bar or the like, but use a wood pad to prevent damage to the core. * Check each pulley for damage, and V-grooves and V-belt for wear. Parti- cularly, check whether V-belt is in contact with bottom of V-groove through wear.

* Replace belt if it has stretched, leaving no allowance for adjustment, or if there is a cut or crack on belt. d. HYDRAULIC FILTER 1. Remove the cap from oil filler (F). 2. Remove cover (I), then remove spring (2) and valve (3), and take out ele- ment (4). 3. Clean the parts after taking them out, then install a new element. A When removing the cap, turn it slowly to relieve inner pressure. A When removing the cover (I), undo the bolts (4 bolts) gradually to pre- vent the cover flying off under the force of the spring (2). * When a hydraulic breaker is installed, the hydraulic oil deteriorates much more rapidly than when carrying out ordinary digging operations with a bucket.

Therefore, change the element for the first time on new machines after 100 - 150 hours, and change the element following this according to the table. (a): Replacement interval (b): (When not using brekaer) (c): Brekaer operation rate (%) (d): (Using only breaker) - 124-