d. CHECK ELECTRICAL INTAKE AIR HEATER Check electrical intake air heater (1) once a year before commencing work in the cold season. Remove electrical intake air heater (1) from the engine intake connection, and check it for possible open-circuits and dirt. When inspecting and replacing electrical intake air heater (I), replace the gasket with new one. e. TRACK SHOE BOLTS If the machine is used with track shoe bolts (1) loose, they will break, so tighten any loose bolts immediately. Method of tightening 1. Tighten first to a tightening torque of 40 + 4 kgm, then check that the nut and shoe are in close contact with the link mating surface. 2. After checking, tighten a further 120” k 10”.
Order for tightening Tighten the bolts in the order shown in the diagram. After tightening, check that the nut and shoe are in close contact with the link mating sur- face. - 152-