Komatsu — OPERATING THE AIR CONDITIONER

Precautions for using air coditioner l When cooling, change the air occasionally. o Smoking in the air-conditioned cab will cause your eyes to get sore. While smoking, open the window to let the smoke out of the cab. 0 While using the air conditioner, open the window once every hour. 0 When using the cooler, make sure the hot water circuit is completely stopped. o If hot water is circulating in the heater, it is like having a hot heater, it is like having a hot water bottle in the cab. Always make sure the heater temperature knob is at the OFF position.

o When not using the heater for a long period, fully close the hot water outlet and inlet valves under the engine water manifold and radiator. l Be careful not to overcool the cab. The cab should feel cool when entering there from outside (5°C or 6°C lower than the outside temperature). It is unhealthy to have the tempera- ture in the cab too low. Always give careful consideration to temperature regulation. INSPECTION AND MAINTENANCE A. Clean air filter If the air filter inlets is clogged, the heating or cooling capacity will drop, Clean the air filter with compressed air once a week. B. Check tension of compressor belt.

If the belt is loose, it will slip and the air conditioner will not be able to cool properly. Periodically press the mid-point of the belt with the finger and check that the deflection is 15 to 18 mm. When the belt is new, it is particularly liable to stretch, so always adjust it after 2 to 3 days. (a): Compressor pulley (b): Drive pulley C. Check volume of refrigerant (gas) If there is a lack of refrigerant, the cooling performance will be poor. When operating the cooler at high speed, there should be no bubbles in the sight glass (inspection window) mounted on the condenser unit receiver. If there are any bubbles, there is a lack of gas, so have to add refriger- ant at a shop. (a):

Sight glass (b): No refrigerant (c): Lack of refrigerant (d): Correct amount of refrigerant - 34 -