Komatsu — HANDLING OF BATTERY

HANDLING OF BATTERY A. PRECAUTIONS FOR CHARGING BATTERY 1. Before charging, disconnect the cable from the negative (-) terminal of the battery. Otherwise, an unusually high voltage will damage the alterna- tor. While charging the battery, remove all battery plugs for satisfactory venti- lation. To avoid gas explosions, do not bring fire or sparks near the battery. If the electrolyte temperature exceeds 45”C, stop charging for a while. Turn off the charger as soon as the battery is charged. Overcharging the battery may cause followings:

1) Overheating the battery 2) Decreasing the quantity of electrolyte 3) Damaging the electrode plate If the electrolyte gets on your skin or clothes, immediately wash with plenty of clean water. Do not mix up cables (positive (+) to negative (-) or negative (-) to positive (+)), as it will damage the alternator. When inspecting or servicing a battery, be sure to stop the engine and turn the starting switch key to “OFF” position. When performing any service to battery besides checking the electrolyte level or measuring the specific gravity, disconnect cables from the bat- tery. 2. 3. 4. 5. 6. 7. 8 B.

REMOVAL AND INSTALLATION OF BATTERY l When removing the battery, first disconnect the cable from the ground (normally, from the negative (-) terminal). If a tool touches a cable con- necting the positive terminal and the chassis, there is danger of sparks being emitted. l When installing the battery, the ground cable should be connected to the ground terminal as the last step. - 38 -