DRESSTA Co. Ltd. TD-15H — 5.8.1. WATER

MAINTENANCE SECTION 5 Page 19 BELTS 5.7.2.2. Checking Tension and Adjustment of A/C Compressor Belt Fig. 5.6. Tension Adjustment of Air Conditioner Compressor Belt A. Air Conditioner Compressor Clamping Bolt (2 pcs) B. Locking Bolt To adjust the belt tension of an air conditioner compressor proceed as follows: 1. Loosen clamping bolts "A" of the compressor and bolts “B". 2. Tense the belt by tilting the compressor till the belt tension is between 270-490 [N] (the deflection under the force of 110 [N] should be 16.5 ± 2 [mm]). 3. Tighten clamping bolts "A" and lock nuts "B". 5.8. COOLING SYSTEM General The cooling system operates under pressure.

The water pump circulates the coolant through the oil cooler, engine block, cylinder heads, and radiator. Circulation is controlled by thermostats, which prevent coolant flow through the radiator until the engine reaches the operating temperature. Proper cooling is assured only when the system is sealed, radiator cap and gasket in good condition, thermostats operate properly, system is free of coolant and/or air flow restrictions and is filled to the proper level. Selection and maintenance of the system coolant is important to long engine life. The following information provides recommendations for selecting engine coolant, maintaining coolant inhibitors, and servicing the cooling system.

This system will operate with a water/antifreeze mixture or inhibited water as a coolant. Never use water alone because water will allow rust, scale deposits, and corrosion to occur within the system. 5.8.1. WATER Use water, which has a low mineral content. Water used in conjunction with antifreeze, coolant filters and inhibited water must meet the following standards: DRESSTA TD-15H