MAINTENANCE SECTION 5 Page 21 COOLING SYSTEM 5.7. Coolant Filter 1. Coolant Filter 2. Shut-off Valve Coolant testing for conditioner concentration Coolant testing for DCA4 concentration should be performed periodically before coolant filter replacement to determine proper capacity of the filter to be applied. CC2626 test kit of the filter manufacturer is designed for this purpose. Replenishing coolant conditioner Replenishing coolant conditioner is performed by periodical replacement of filters containing DCA4 inhibitor protecting the cooling system against corrosion and cavitation erosion of the cylinder sleeves and coolant pump blades.
Prior to installation of a new coolant filter close the shut-off valve on the coolant filter head (OFF). Upon the installation of a new coolant filter open the shut-off valve (ON). NOTE: Mixing of DCA4 and other supplemental coolant additives is not recommended because there is currently no test kit available to measure concentration levels with mixed chemical solutions. 5.8.4. RADIATOR CAP General Radiator cap (2) seals the coolant filler opening of the radiator. Positive sealing requires a cap gasket and its contacting surfaces in good condition, and a properly tightened cap.
Radiator cap cover (1) incorporates a pressure relief valve that keeps the pressure of coolant at 40 – 55 [kPa] in the top tank of the radiator. IMPORTANT: Operating a machine without the radiator cap, or with a cap without a relief valve set to operate at the correct pressure can cause damage. DRESSTA TD-15H