SECTION 5 MAINTENANCE Page 22 COOLING SYSTEM Fig. 5.8. Radiator Cap and Coolant Level Sight Gauge 1. Radiator Cap Cover 2. Radiator Cap 3. Sight Gauge Removal To remove the cap turn if to the left or counterclockwise up to the safety stop until all pressure is released. Then press down on the cap and continue to turn until the cap is free to be removed. Installation When installing a cap, the gasket and contacting surfaces must be clean. Turn the cap to the right or clockwise until snug. 5.8.5. CHECKING COOLANT LEVEL IMPORTANT: Check the coolant level before starting the engine. 1. Check the coolant level daily to be sure that the level is proper.
Coolant level must be seen in the sight gauge (3, Fig. 5.8). 2. For checking coolant level place the machine on the level ground and lower the mounted equipment to the ground. 3. If coolant has to be added, remove the radiator cap (Refer to 5.8.4) and pour the coolant until it is visible in the sight gauge. 5.8.6. CLEANING THE RADIATOR CORE Every 50 hours of operation remove dirt from the radiator core blowing it through with compressed air in the direction opposite to the fan. TD-15H DRESSTA