SECTION 6 SPECIFICATIONS Page 12 6.7. TORQUE VALUES FOR SPLIT FLANGE CONNECTIONS The following chart provides the tightening torques for split flange connections used in hydraulic systems. Split flanges and fitting shoulders should fit squarely. Install all bolts, finger tight and then torque evenly. Over torquing bolts will damage the flanges and/or bolts, which may cause leakage. Bolt size [in] Flange size [in]* Torque Value [Nm] 1/2 3/4 1 1- 1/4 1- 1/2 2 2- 1/2 3 3- 1/2 5/16 3/8 3/8 7/16 1/2 1/2 1/2 5/8 5/8 20–24 30–37 37–47 47–61 62–79 75–88 107–123 187–203 159–180 * – Inside diameter of hydraulic tube or hose fitting. 6.8. TORQUE VALUES FOR HYDRAULIC TUBES AND FITTINGS Size Tubing o.d.
in inches Thread size in inches Torque values for 37 [°] flared fittings Torque values for O-ring boss plugs, locknuts and 37 [°] flared fittings 4 5 6 8 10 12 14 8–14 14–20 20–27 34–41 47–54 81–95 95–109 16 20 24 32 ј 5/16 3/8 1/2 5/8 3/4 7/8 7/16–20 1/2 –20 9/16–18 3/4 –16 7/8–14 1-1/16–12 1-3/16–12 12–16 16–20 29–33 47–54 72–79 104–111 122–138 1 1- 1/4 1- 1/2 2 1-5/16–12 1-5/8–12 1-7/8–12 2-1/2–12 149–163 190–204 217–237 305–325 108–122 129–156 163–190 339–407 Above torque figures are recommended for plain, cadmium or zinc plated fittings, dry or wet installations. These torques are not recommended for tube with wall thickness of 0.9 [mm] or less. DRESSTA TD-15H