OPERATING SECTION 4 Page 31 OPERATING MOUNTED EQUIPMENT NOTE: This adjustment is made such that gaps are provided as shown in Figs. 4.29 and 4.30 . 8. Install the mounting pins aligning the lock holes and secure with locking hardware. Retorque the strut eyebolt clamping cap screws and nuts to 450 [Nm]. Fig. 4.29. Lower Strut Adjustment of the Angled Blade. 1. Trunnion Swivel Eye 2. Gap 9. Level the blade so one end does not dig in deeper than the other. This can be done by adjusting either or both upper struts. Refer to “LEVELLING THE BLADE” Fig. 4.30. Swivel Pin Adjustment Gap. 1. C-frame 2. Swivel Pin 3. Gap DRESSTA TD-15H