ELECTRICAL SYSTEM - DISASSEMBLY, INSPECTION AND REASSEMBLY (2) Inspecting the armature (a) Using a dial gauge, measure the commutator for radial runout. If the measure value is equal to or exceeds the limit, correct (within the diameter limit) or replace. Unit: mm (in.) Commutator Standard value Limit Measuring the commutator radial runout (b) Measure the commutator diameter. If the measured value is equal to or less than the limit, replace. Unit: mm (in.) Diameter (c) Measure the depth of undercutting between the commutator segments. If the measured value is equal to or less than the limit, correct or replace. Unit:

mm (in.) Measuring the commutator diameter Undercutting Segment Mica (d) Armature coil short circuit Using a growler, test the armature coil for short circuit. Replace if short circuit is indicated. How to inspect: (Before inspection, remove any debris from the armature coil.) With a thin iron plate positioned parallel with the armature coil, slowly rotate the armature coil. While the coil is running, the iron plate should not be pulled onto the coil or vibrate.

Measuring the mica undercutting depth Iron plate Growler Testing the armature coil for short circuit 7 - 13 Commutator radial runout M001T68281 0.05 (0.002) 0.10 (0.004) M008T70471A M008T81071A 0.03 (0.001) Standard value Limit Commutator diameter M001T68281 29.4 (1.16) 28.8 (1.13) M008T70471A M008T81071A 32.0 (1.26) 31.4 (1.24) Standard value Limit Mica undercutting depth M001T68281 M008T70471A M008T81071A 0.5 (0.02) 0.2 (0.01)