ELECTRICAL SYSTEM - DISASSEMBLY, INSPECTION AND REASSEMBLY 2.2 Inspecting and correcting the alternator (1) Inspecting the diodes Perform continuity test on each of the rectifier diodes in the following manner. (a) Connect a tester between the diode lead terminal and the casing of that diode. A great resistance should be indicated in one direction and a small resistance in the opposite direction. (b) If the same level of resistance is indicated in both directions, replace the rectifier. Perform this test on all diodes. (2) Inspecting the field coils (a) Measure between the slip rings. Replace if no continuity is indicated (open circuit).
(b) Measure between the slip ring and the shaft (or the core). Replace if continuity is indicated. Inspecting the diodes Testing the field coils for open circuit Testing the field coils for continuity 7 - 20