ELECTRICAL SYSTEM - DISASSEMBLY, INSPECTION AND REASSEMBLY Stop solenoid with 3-pole waterproof connector (1) Apply sealant onto the threaded portion of the stop solenoid. Note: Apply sealant only to the area that will be concealed by the governor case when installed. Tightening torque: 39.2 to 49.0 N m (4.0 to 5.0 kgf m) [28.9 to 36.2 lbf ft] These areas should be free of sealant. (2) Loosely install the stop solenoid and the nut onto the governor case. (3) Move the fuel injection pump control rack fully to the stop position. (4) While pushing the plunger, screw in the stop solenoid until the shaft contacts the tie-rod.
(5) Back off the stop solenoid by 30° to 45° from the position achieved in step (4) above until the clearance between the rack and the plunger becomes 0.15 to 0.20 mm (0.006 to 0.008 in.). Tighten the nut to the specified torque. (6) Start the engine. When the plunger is fully pushed in, the engine should stop. 3.2 Checks after reassembly (1) Start the engine and turn the key OFF. The solenoid should trip, causing the engine to stop. (2) With the engine running, ground the oil pressure switch terminal to the switch body. The engine should stop. 4. Glow Plug Inspecting the glow plug Measure between the terminal and the body.
Replace if no continuity is indicated or the resistance measured is too great. Unit: Ω 0.15 to 0.50 mm (0.006 to 0.008 in.) Shaft Threaded portion: Apply sealant. Installing the stop solenoid Inspecting the glow plug 7 - 24 Sealant ThreeBond 1212 Standard value Resistance 0.55