ELECTRICAL SYSTEM - DISASSEMBLY, INSPECTION AND REASSEMBLY 3. Stop Solenoid 3.1 Reassembling the stop solenoid Stop solenoid with rubber cap and plugs (1) Apply sealant onto the threaded portion of the stop solenoid. Note: Apply sealant only to the area that will be concealed by the governor case when installed. Tightening torque: 39.2 to 49.0 N 㨯 m (4.0 to 5.0 kgf 㨯 m) [28.9 to 36.2 lbf 㨯 ft] These areas must be free of sealant. Sealant ThreeBond 1212 (2) Loosely install the stop solenoid and the nut onto the governor case. (3) Move the fuel injection pump control rack fully to the stop position.
(4) While pushing the plunger, screw in the stop solenoid until the plunger contacts the control rack. At this position the clearance A should be 0 mm (0 in.) (the position where the plunger is screwed in along with the stop solenoid). (5) Back off the stop solenoid by 30° to 45° from the position achieved in step (4) above until the clearance between the rack and the plunger becomes 0.15 to 0.20 mm (0.006 to 0.008 in.). Tighten the nut to the specified torque. (6) Start the engine. When the plunger is fully pushed in, the engine should stop. (7) Install the rubber cap so that the arrow points upwards (the water drain faces downwards) as illustrated.
Clearance A 0 mm (0 in.) Shaft 0.15 to 0.20 mm (0.006 to 0.008 in.) Threaded portion: Apply sealant. There should be no intrusion/leak of cleaning fluid through the gap into the solenoid Installing the stop solenoid Rubber cap Ensure that the solenoid terminals and inner parts (wiring and shaft) will not be exposed to cleaning fluid. Water drain Installing the rubber cap 7 - 23