MAINTENANCE. SERVICE PROCEDURE a) Low pressure i) Check for leaks. ii) Consult your distributor to recharge system. b) High pressure i) Check for blockages in piping. Check in off-season When not being used for a long period, operate the cooler for 3 to 5 minutes once a month to supply lubricant to each component of the compressor. Inspection and maintenance items list for cooler DRAIN ENGINE BREATHER OIL CATCHER Periodically drain oil from the engine breather catcher and when- ever it is necessary to remove the engine undercover. 1. Remove plug (1) from engine undercover (3) and allow oil to drain out. 2. Replace plug (1).
Ensure that the breather hose (2) is positioned onto catcher res- ervoir whenever the undercover is removed. 203 Inspection and maintenance items Contents Maintenance interval Refrigerant (gas) Filling quantity Twice a year; spring and autumn Condenser Clogging of fin Every 500 hours Compressor Function Every 4000 hours V belt Damage and tension Every 250 hours Blower motor and fan Function (Check for normal sound) When required Control mechanism Function (Check for function) When required Piping for connection Installation condition looseness of tightening connection portion gas leakage, damage When required