Komatsu — CHECK AIR CLEANER FOR CLOGGING

SERVICE PROCEDURE MAINTENANCE. CHECK OIL LEVEL IN HYDRAULIC TANK, ADD OIL When removing the oil filler cap, oil may spurt out, so turn the cap slowly to release the internal pressure before removing the cap. If oil has been added to above the H mark, stop the engine and wait for the hydraulic oil to cool down, then drain the excess oil from drain plug (P). 1. If the work equipment is not in the condition shown in the dia- gram on the right, start the engine run the engine at low speed, retract the arm and bucket cylinders, then lower the boom, set the bucket teeth in contact with the ground, and stop the engine. 2. Check sight gauge (G). The oil level is normal if between the H and L marks.

NOTE: Do not add oil if the level is above the H line. This will damage the hydraulic equipment and cause the oil to spurt out. 3. If the level is below the L mark, remove cap (F) from the hydraulic tank and add oil. For details of the oil to use, see “USE FUEL, COOLANT AND LUBRICANTS ACCORDING TO AMBIENT TEMPER- ATURE” on page 177. REMARK The oil level will vary depending upon the oil temperature. Accordingly, use the following as a guide: Before operation: around L level (Oil temperature 10 to 30°C) Normal operation: around H level (Oil temperature 50 to 80°C). CHECK AIR CLEANER FOR CLOGGING 1. Confirm that the air cleaner clogging monitor does not flash (1). 2.

If it flashes, immediately clean or replace the element. For details of the method of cleaning the element, see “CHECK, CLEAN AND REPLACE THE AIR CLEANER ELEMENT” on page 192. 1 AD313590A 206 WARNING