MAINTENANCE. SERVICE PROCEDURE CHECK ELECTRIC WIRING If the fuse blows frequently, or there are traces of short-cir- cuiting in the electric wiring, always locate and repair the cause. Check for damage of the fuse and any sign of disconnection or short circuit in the electric wiring. Check also for loose terminals and tighten any loose parts. Check the following points carefully. Battery Starting motor Alternator Please contact your Komatsu distributor for investigation and cor- rection of the cause. CHECK FOR WATER AND SEDIMENT IN SEDIMEN- TOR. DRAIN WATER AND SEDIMENT A fuel sedimentor is mount in the radiator compartment and is accessed by the door on the left hand side of the machine.
Entrapped sediment and water can be seen through the glass bow. 1. Loosen drain plug (1) and drain water and sediment until none is visible in bowl. 2. Tighten drain plug. CHECK FOR WATER IN PRIMARY FUEL FILTER, DRAIN WATER A primary fuel filter is fitted in the pump compartment. Drain the water from the primary fuel filter by turning cap at the bottom of the filter. 207 WARNING (A): Fuel (B): Water/sediment