AIR CLEANERS AND FUEL SYSTEM-N.11 Fuel Pipes (High Pressure) When replacing the fuel pipes it should be noted that no two pipes are the same, each is formed to suit an individual atomiser position. This is important when ordering a replacement pipe, as each one has a different part number. High pressure fuel pipes are now supplied with formed ends instead of olives. The earlier pipes supplied with olives were fitted as shown in Fig. N.21. Originally the olives were fitted in the reverse position, but both positions are satisfactory if undamaged. N22 3. Ensure that the stop control is in the 'run' position.
if an electric solenoid stop control is used, turn the key of the start switch to the 'R' position. Set the throttle to fully open. 4. Loosen the vent screw on top of the control gear housing, on hydraulically governed fuel pumps (see Fig. N 19) or on the rear of the governor housing on mechanically governed fuel pumps, (1, Fig. N23). Loosen the vent screw in the locking bolt of the hydraulic head, (2, Fig. N23), for both types of fuel pump. Operate the priming lever on the fuel lift pump until fuel, free of air, flows from the vents. Tighten the vent screw in the locking bolt of the hydraulic head and then the vent screw on the governor housing or control gear housing. 5.
Where a Thermostart cold starting aid is fitted and the fuel pipe has been drained, loosen the pipe connection at the starting aid. Operate the priming lever of the lift pump until fuel, free of air, flows from the connection and tighten the connection. 6. Loosen the pressure pipe connections at N21 The pipes should be clean, (wash in clean fuel oil and blow through the fine bore with compressed air if there is any doubt), the olives at each end should not be split or unduly compressed, otherwise leakage will result and a new pipe will be needed. Ensure when fitting, that the pipe fits squarely at both ends and that the union nuts are tightened firmly but not over-tightened.
The correct tightening torque for high pressure fuel pipe nuts is 15 Ibf ft (2,1 kgf m) or 20 Nm. When changing an atomiser always remove the pipe completely. two of the atomisers. Ensure that the manual stop control, if fitted, is in the run position. Operate the starter motor until fuel, free of air, comes from the pipe connections, tighten the high pressure pipe connections. The engine is now ready to start. If after priming the fuel system, the engine starts, runs satisfactorily for a few minutes and then loses power, misfires or stops and when checked the system is found to be full of air, then a leak on the suction side is indicated.
The air must be vented from the fuel system whenever any part of the system between the fuel tank and in- jection pump has been disconnected for any reason, or when the system has been emptied of fuel. No attempt must be made to start the engine until the injection pump has been filled and primed as serious damage can be caused to the pump due to lack of lubrication. The method of priming detailed below, ensures that only fuel which has passed through the paper filter element can reach the interior of the pump. 1. Loosen the vent screw (1, Fig. N22) on top of the filter. Where a vent screw is not fitted, loosen the return to tank banjo bolt (2) on top of the filter. 2.
Operate the priming lever on the fuel lift pump (see Fig. N7) and when fuel, free of air, flows from the vent or banjo connection, tighten the vent screw or banjo bolt. If the drive cam of the fuel lift pump is at maximum lift it will not be possible to operate the lift pump and the -' crankshaft must be turned through one revolution. N23 4.108 Series Workshop Manual, June 1986